Shop STB / Someco Pneumax Control Valve
1 / 6
STB / Someco Pneumax Control Valve Image 1 of 6
STB / Someco Pneumax Control Valve
STB / Someco Pneumax Control Valve leak Image 2 of 6
STB / Someco Pneumax Control Valve leak
STB Welder Valve Location Image 3 of 6
STB Welder Valve Location
STB or Someco  welder valves Image 4 of 6
STB or Someco  welder valves
STB SL3 / SL4 welders valve Image 5 of 6
STB SL3 / SL4 welders valve
replacement valve for Stb or wegoma welder Image 6 of 6
replacement valve for Stb or wegoma welder

STB / Someco Pneumax Control Valve

£98.50

Pneumax Control Valve for STB and SOMECO Inline Welders

Usually located on Manifolds in the Base of the Machine

Older Valves Tended to be Gold in Colour, Newer Valves are Grey (Same Product)

Faults indicating a valve needs replacing include:

  • Large Air Leak

  • Cylinders or some operation of the machine not working as intended

  • Compressor working extra hard to keep up

  • Weld Cycle not completing

Valves usually Fail internally with the seals disintegrating and clogging up the silencers, usually there’s a pretty huge air leak but its quite well muffled

New Valves are supplied with New Silencers fitted and New Coils, As some very old valves had a different size stem so not all coils would be interchangeable

Its an easy bolt on change, unscrew old valve clean off manifold to avoid leaving any seals behind, bolt new one on and then swap power plug loosening center screw to remove that

It is Quite common to find more leaks once you fix the loudest leak, there are usually banks of 7 valves in the machine (Depending on size) and they do tend to go at a similar time

All Prices Plus VAT and Delivery UK Shipping only

Quantity:
Add To Cart

Pneumax Control Valve for STB and SOMECO Inline Welders

Usually located on Manifolds in the Base of the Machine

Older Valves Tended to be Gold in Colour, Newer Valves are Grey (Same Product)

Faults indicating a valve needs replacing include:

  • Large Air Leak

  • Cylinders or some operation of the machine not working as intended

  • Compressor working extra hard to keep up

  • Weld Cycle not completing

Valves usually Fail internally with the seals disintegrating and clogging up the silencers, usually there’s a pretty huge air leak but its quite well muffled

New Valves are supplied with New Silencers fitted and New Coils, As some very old valves had a different size stem so not all coils would be interchangeable

Its an easy bolt on change, unscrew old valve clean off manifold to avoid leaving any seals behind, bolt new one on and then swap power plug loosening center screw to remove that

It is Quite common to find more leaks once you fix the loudest leak, there are usually banks of 7 valves in the machine (Depending on size) and they do tend to go at a similar time

All Prices Plus VAT and Delivery UK Shipping only

STB Heater Plate Spring Plate (Stainless version)
STB Heater Plate Spring Plate (Stainless version)
£9.80

Pneumax Control Valve for STB and SOMECO Inline Welders

Usually located on Manifolds in the Base of the Machine

Older Valves Tended to be Gold in Colour, Newer Valves are Grey (Same Product)

Faults indicating a valve needs replacing include:

  • Large Air Leak

  • Cylinders or some operation of the machine not working as intended

  • Compressor working extra hard to keep up

  • Weld Cycle not completing

Valves usually Fail internally with the seals disintegrating and clogging up the silencers, usually there’s a pretty huge air leak but its quite well muffled

New Valves are supplied with New Silencers fitted and New Coils, As some very old valves had a different size stem so not all coils would be interchangeable

Its an easy bolt on change, unscrew old valve clean off manifold to avoid leaving any seals behind, bolt new one on and then swap power plug loosening center screw to remove that

It is Quite common to find more leaks once you fix the loudest leak, there are usually banks of 7 valves in the machine (Depending on size) and they do tend to go at a similar time

All Prices Plus VAT and Delivery UK Shipping only

You Might Also Like:

KPM PNEUMATIC CLAMP CYLINDER 220mm KPM LONG CLAMP CYLINDER HEX ROD KMP_Cylinder_220mm_Square.jpg KMP_Cylinder_M10_Thread_End_V2.jpg KMP_Cylinder_Port_1.8_bsp_Thread_End.jpg KMP_Cylinder_M10_Thread_End.jpg KPM Hex Rod 220mm Long Clamp Cylinders RJ035L0140 40mm Dia Clamp Cylinder  kpm carpi Window Clamping Part Saw Air Clamp KPM Saw Pneumatic Clamping Cylinder  kpm carpi
KPM PNEUMATIC CLAMP CYLINDER 220mm
£57.99
Gas Strut for Pertici FC106 Gas Strut for Pertici 106 Copy Router Machine Window Machine Consumable FC106 Gas Strut Pertici
Gas Strut for Pertici FC106
£65.99
MIST SPRAY COOLANT UNIT KPM KPM TA000330 Mist Spray Unit KPM TA000330 Mist Spray Unit KPM TA000330 Mist Spray Unit KPM TA000330 Mist Spray Unit
MIST SPRAY COOLANT UNIT KPM
£39.98
Graule ZS200N Table Graule ZS200N Table Graule ZS200N Table Graule ZS200N Table
Graule ZS200N Table
£196.00
Pertici 332 IP Double Mitre Saw Pertici 332 IP Double Mitre Saw Pertici 332 IP Double Mitre Saw Pertici 332 IP Double Mitre Saw Pertici 332 IP Double Mitre Saw
Pertici 332P/IP Wire Rope
£15.00

Newsletter sign up

Sign up for our newsletter to see new arrivals, learn about special offers, and more.

Thank you!

CKMACHINERY.COM   email:Sales@ckmachinery.com    TEl: 01934 625850

Home Router Cutters Contact

STB / Someco Pneumax Control Valve
STB / Someco Pneumax Control Valve leak
STB Welder Valve Location
STB or Someco  welder valves
STB SL3 / SL4 welders valve
replacement valve for Stb or wegoma welder